Abstract : The experiment to know the performance of thermoacoustic heat pump performance using the length of pipe of 70 cm, diameter 4,6 cm, and the stack material which consists of plastic with the length of 10 cm and circle pore varied diameter has been done. The method to determine stack pore optimum diameter is by placing the stack center position at ? / 20, which in measured from the tube end, and input voltage is 15 volt for 10 minutes operation on the resonance frequency. The result of this experiment, on the resonance frequency 127 Hz, it is obtained that the optimum stack pore diameter is at 3,61 mm with the temperature difference between hot and cool reservoirs is around of 19 °C.