Title : Design considerations for improvement of speech intelligibility and privacy in a hospital intensive care unit
Author :

Ir. Sentagi Sesotya Utami, S.T., M.Sc., Ph.D. (1) Joko Sarwono (3) RANDY FRANS FELA (4) Iva Rofiatun Nisa Azzahra (5)

Date : 0 2017
Keyword : %Alcons Distraction distance Hospital Speech privacy distance Sti %Alcons Distraction distance Hospital Speech privacy distance Sti
Abstract : Acoustics problems that mainly occur in an ICU are noises from medical staff activities and equipment. Excessive sound from human conversation is considered as unwanted noise. Activities within the ICU requires the staff movements, which also creates non-stationary conversation area especially near the patient's bed. Despite of this condition, nurse station is the location where the noise produced from conversation will raise significantly and where lack of speech privacy becomes a concern and higher chance of less confidentiality of medical information. The research is based on computer modeling that enables inclusion of scattering effects. By principle, the acoustical treatment in a nurse station is to avoid speech leakage from this area as well as to improve the speech intelligibility. Several improvement ideas is by installing hanging abfussor at the nurse station, hanging abfussor near the patient bed, and a glass partition at the nurse station. The speech privacy distance (rP) and distraction distance (rD) can be predicted using ISO 3328-3:2012 method and %Alcons formula based on the STI values. To evaluate the effectiveness of the improvement, an auralization scenario of the activities within the ICU is used in a survey. All the improvement design proposed did not create significant impact to the acoustic quality based on the rP and rD values. However, this paper demonstrates a good technique to predict the range of easiness of nurses' communication in their workspace while they continuously move. It is given by the distraction distance that is used here to predict speech intelligibility of certain source to receiver distance. The result is a guideline for nurse station design optimization using three design approaches above by utilizing abfussor (absorber and diffuser) as part of the building interior.
Group of Knowledge :
Level : Internasional
Status :
Published
Document
No Title Document Type Action
1 ICSV24_DESIGN CONSIDERATIONS FOR IMPROVEMENT OF SPEECH INTELLIGIBILITY AND PRIVACY IN A HOSPITAL ICU.pdf
Document Type : Bukti Published
Bukti Published View
2 prosiding_2022250_cea09b0b1fab6a3d34d02a1951ad32f7.pdf
Document Type : [PAK] Full Dokumen
[PAK] Full Dokumen View
3 Bukti korespondensi ICSV24_Acceptance Letter etc.pdf
Document Type : Bukti Accepted
Bukti Accepted View
4 Design considerations for improvement of speech intelligibility and privacy in a hospital intensive care unit.pdf
Document Type : Dokumen Pendukung Karya Ilmiah (Hibah, Publikasi, Penelitian, Pengabdian)
Dokumen Pendukung Karya Ilmiah (Hibah, Publikasi, Penelitian, Pengabdian) View
5 DESIGN CONSIDERATIONS FOR IMPROVEMENT OF SPEECH INTELLIGIBILITY AND PRIVACY IN A HOSPITAL INTENSIVE CARE UNIT.pdf
Document Type : Cek Similarity
Cek Similarity View
6 Design considerations for improvement of speech intelligibility and privacy in a hospital intensive care unit (1)_compressed.pdf
Document Type : [PAK] Full Dokumen
[PAK] Full Dokumen View