ACADSTAFF UGM

CREATION
Title : DESIGN OF EXTRA CAVITY PHOTOACOUSTIC SPECTROMETER BASED ON BLUE DIODE LASER IN NO2 (NITROGEN DIOXIDE) GAS DETECTION
Author :

HARJUM (1) Prof. Dr. Agung Bambang Setio Utomo, S.U. (2) Prof. Dr. Mitrayana, S.Si., M.Si. (3)

Date : 0 2021
Keyword : Blue Laser Photoacoustic Spectrometer,Nitrogen dioxide,Photoacoustic Cell,Modulation,Arduino Uno Blue Laser Photoacoustic Spectrometer,Nitrogen dioxide,Photoacoustic Cell,Modulation,Arduino Uno
Abstract : NO2 detection is necessary because NO2 is an air pollutant causing photochemical smog and acid rain. In addition, respiratory diseases are caused by high levels of NO2 in the inhaled air. Aim: The purpose of this study was to detect NO2 using PAS utilizing Arduino Uno, an easy, simple, and low-cost research. Methods: The detection of Nitrogen Dioxide (NO2) gas with a Photoacoustic Spectrometer (PAS) using an Arduino Uno microcontroller has been carried out. The PAS system uses a blue diode laser with a wavelength of 450 nm as the radiation source because this wavelength is suitable for NO2 gas. The intensity of the laser beam is modulated using a modulation system with an on-off scheme using the Arduino Uno. The modulation frequency has been varied to get the maximum detection frequency. The photoacoustic cell used was a single resonator photoacoustic cell with type H. Sound sensor and photodiode were used in this measurement. The amplification of the signal was done by utilizing the Lock-in amplifier, and the constant time of Lock-in amplifier was also determined to optimize the PAS. Nitrogen gas was used to detect background signal. Results and Discussion: From the photoacoustic spectrometer optimization, the results obtained were a laser diode frequency of 1,000 Hz with a duty cycle of 50% and a Lock-in amplifier amplification of 10,000 times with a constant time of 3.3 ms. The maximum concentration reached in this measurement was 6 ppm. The background signal achieved in this measurement was 0.00002 V/W. The lowest detection limit achieved in this measurement was 0.0064 ppm
Group of Knowledge : Fisika
Original Language : English
Level : Internasional
Status :
Published
Document
No Title Document Type Action
1 halaman muka jurnal.pdf
Document Type : [PAK] Halaman Cover
[PAK] Halaman Cover View
2 halaman editorial jurnal.pdf
Document Type : [PAK] Halaman Editorial
[PAK] Halaman Editorial View
3 daftar Isi jurnal.pdf
Document Type : [PAK] Daftar Isi
[PAK] Daftar Isi View
4 paper lengkap harjum 2021.pdf
Document Type : [PAK] Full Dokumen
[PAK] Full Dokumen View
5 cek turnitin_RANCANG BANGUN SPEKTROMETER FOTOAKUSTIK EKSTRAKAVITAS BERSUMBERKAN LASER DIODA BIRU DALAM PENDETEKSIAN GAS NO2 (NITROGEN DIOKSIDA) (1).pdf
Document Type : [PAK] Cek Similarity
[PAK] Cek Similarity View